Magnetic sensors for round cylinders MI, MA, MF, PB, MAL series

Peste 14 ani de experienta in domeniu!

  • Check Mark Promptitudine, raspunsuri si solutii rapide!
  • Check Mark Livrare rapida - predare curier in aceeasi zi!
  • Check Mark Baza de date (fise tehnice) complexa
SKU: CS1-M

Description

Magnetic sensors for round cylinders MI, MA, MF, PB, MAL series

Code CS1-M

Specifications

Dimensions Cs1-M sensors

Ordering code

Mounting method:

Encircle the bandage around the outside of the cylinder body and make it closely next to the cylinder wall. Snap the clamping screw into the button orifice and adjust it to the proper position. properly tighten the clamping screw to fix.

Instructions:

  1. Sensor shall not fall down or bear great impact when it is installed.
  2. The wire of the sensor shall not move with the action of the cylinder.
  3. Clamping torque shall be within the allowable scope when the sensor is installed (0.15~0.2Nm).
  4. Sensor shall be installed in the middle position of the action scope.
  5. Sensor wiring:
    1. The wire is unable to bear repetitive torsion and tension. Please wire an external load before switching the power on.
    2. No poor insulation in wire.
    3. Do not wire with power line, high voltage line or use one wiring pipe.
    4. Please wire the circuit correctly based on the circuit diagram.
  6. Execute scheduled maintenance by the following guidelines:
    1. make sure the sensor is firmly fixed
    2. make sure the wire is intact
    3. make sure that LED indicate the movement of the cylinder correctly
  7. Other indications:
    1. It is forbidden to use the sensor in the environment with explosive gas.
    2. Magnetic sensors shall not be used in the environment with external magnetism.
    3. Magnetic sensors shall not be used in the environment that is always eroded by water.
    4. Magnetic sensors shall not be used in the environment with oil moisture or chemical substances.
    5. Magnetic sensors shall not be used in the environment with periodically changing temperature.
    6. Magnetic sensors shall not be used in the environment with excessively great impact.
    7. Magnetic sensors shall not be used in the environment with sources of electrical pulse.
    8. Avoid the environment with accumulated iron powder and dense magnetic objects.

Additional information

Brand

Usual Product Codes

3D Product Sheet